MRI EVALUATION OF SHOULDER STABILIZER INJURIES USING DIXON MRI: DEVELOPMENT OF A COMPREHENSIVE DIAGNOSTIC ALGORITHM
Keywords:
shoulder joint; magnetic resonance imaging; Dixon MRI; shoulder instability; rotator cuff; static stabilizers; dynamic stabilizers; fatty degeneration; diagnostic algorithmAbstract
Objective:To develop and clinically evaluate a comprehensive magnetic resonance imaging algorithm for assessment of static and dynamic shoulder stabilizer injuries using a standardized MRI protocol supplemented with Dixon MRI quantitative analysis.
Materials and Methods: A retrospective and prospective diagnostic study included 116 patients with injuries of the shoulder stabilizing apparatus. MRI examinations were performed on a 1.5 Tesla scanner using a standardized protocol including PD, PD-FS, T1-weighted, T2-weighted, STIR, and Dixon MRI sequences. Assessment included the glenoid labrum, capsuloligamentous complex, bone structures, rotator cuff, tendon retraction, muscle atrophy, and fatty degeneration. MRI findings were correlated with arthroscopic data in patients undergoing surgical treatment.
Results: Among 116 patients, the mean age was 42.1 ± 18.1 years. Men comprised 74 patients (63.8%), and women comprised 42 patients (36.2%). Dynamic stabilizer injuries were identified in 52 patients (44.8%), static stabilizer injuries in 30 patients (25.9%), and combined lesions in 34 patients (29.3%). Static stabilizer injuries were mainly characterized by labral lesions, Hill–Sachs defects, glenoid bone changes, and capsuloligamentous abnormalities. Dynamic stabilizer injuries demonstrated predominant rotator cuff pathology, tendon retraction, muscle atrophy, and fatty degeneration. Dixon MRI enabled quantitative assessment of chronic muscular changes through evaluation of fat fraction. In patients with fat fraction values exceeding 20%, diagnostic sensitivity was 97.1%, specificity 98.8%, and overall diagnostic accuracy 98.3%.
Quantitative Dixon MRI analysis demonstrated significant differences between acute and chronic shoulder stabilizer injuries. Patients with chronic lesions showed higher fat fraction values compared with acute injuries (26.7 ± 7.2% vs 12.4 ± 4.8%, p<0.001), increased muscle atrophy (21.5 ± 8.4% vs 8.6 ± 3.9%, p<0.001), and greater tendon retraction (18.4 ± 9.6 mm vs 6.2 ± 3.1 mm, p<0.001). MRI findings showed excellent correlation with arthroscopic results (sensitivity 97.1%, specificity 98.8%, accuracy 98.3%, Cohen’s κ=0.91; p<0.001).
Conclusion: The developed comprehensive MRI algorithm allows transition from isolated assessment of individual shoulder lesions to systematic evaluation of the entire stabilizing apparatus. Integration of Dixon MRI into a standardized MRI protocol improves characterization of chronic degenerative changes, facilitates differentiation between acute and chronic injuries, and may optimize clinical decision-making and treatment planning.
References
Иванков А.П., Селиверстов П.В., Меньшова Д.В. Опыт применения дополнительного субмиллиметрового 3D-FSE режима (3D-PD-FS-ВИ) в МРТ-диагностике полного и частичного разрывов сухожилия надостной мышцы плечевого сустава (клиническое наблюдение) // Радиология - практика. - 2024. - № 4 (106). - С. 67-78.
Ирисметов М.Э., Салиев С.М., Ражабов К.Н. и др. Современные методы диагностики разрывов вращательной манжеты плечевого сустава (литературный обзор) // Травматология, ортопедия и реабилитация. - 2024. - № 2. - С. 72-76.
Кезля О.П., Маслов А.П., Ярмолович В.А., Бенько А.Н., Ладутько Ю.Н., Селицкий А.В. Повреждения ротаторной манжеты плеча: диагностика и открытые операции в лечении: учеб.-метод. пособие. – Минск: БелМАПО, 2022. – 66 с.
Панина О.Ю., Громов А.И., Ахмад Е.С., Семенов Д.С., Кивасев С.А., Петряйкин А.В., Васильев Ю.А., Нечаев В.А. Возможности МРТ последовательностей DIXON в количественной оценке жировой фракции: фантомное исследование. // Digital Diagnostics. - 2025. - Т. 6. - №2. doi: 10.17816/DD633802
Тицкая Е.В., Кабаев Е.М., Симонов К.В., Мацулев А.Н. Метод интерпретации данных изокинетических тестов и МРТ исследований во время реабилитации пациентов после рекон-структивной хирургии плечевого сустава // Медицина и высокие технологии. - 2021. - № 2. - С. 22-33.
Финк Л.И., Попов А.П. Лучевые методы исследования в диагностике повреждений мягкотканных структур плечевого сустава в условиях военного консультативно-диагностического центра // Военно-медицинский журнал. - 2018. - Т. 339, № 4. - С. 57-60.
Ямщиков О.Н., Емельянова Н.В., Чумаков Р.В., Левина А.В. Особенности визуализации при травматических поражениях плечевого сустава // Медицинский альянс. - 2024. - Т. 12, № 3. - С. 91-96.
Bainbridge A, Bray TJP, Sengupta R, Hall-Craggs MA. Practical approaches to bone marrow fat fraction quantification across magnetic resonance imaging platforms. Journal of Magnetic Resonance Imaging. 2020;52(1):298–306. doi: 10.1002/jmri.27039 EDN: WCMNIG
Bhat V, Velandai S, Belliappa V, et al. Quantification of liver fat with mDIXON magnetic resonance imaging, comparison with the computed tomography and the biopsy. Journal of Clinical and Diagnostic Research. 2017;11(7):TC06–TC10. doi: 10.7860/JCDR/2017/26317.10234
Furrer P.R., Borbas P., Egli R.J., Zindel C., Wieser K., Bouaicha S. MRI findings of traumatic and degenerative rotator cuff tears and introduction of the “cobra sign” // JSES International. – 2023. – Vol. 7, № 4. – P. 632–640. – DOI: 10.1016/j.jseint.2023.02.013.
Gromov AI, Gorinov AV, Galljamov EA. Mesenteric chillous lymphangioma. Visualization features on opposed-phase MR images. Medical Visualization. 2019;23(4):86–92. doi: 10.24835/1607-0763-2019-4-86-92 EDN: UCRGCC
Horiuchi S., Nozaki T., Tasaki A., Yamakawa A., Kaneko Y., Hara T. et al. Reliability of MR quantification of rotator cuff muscle fatty degeneration using a 2-point Dixon technique in comparison with the Goutallier classification: validation study by multiple readers // Academic Radiology. – 2017. – Vol. 24, № 11. – P. 1343–1351.
Matsumura N., Oguro S., Okuda S., Jinzaki M., Matsumoto M., Nakamura M., Nagura T. Quantitative assessment of fatty infiltration and muscle volume of the rotator cuff muscles using 3-dimensional 2-point Dixon magnetic resonance imaging // Journal of Shoulder and Elbow Surgery. – 2017. – Vol. 26, № 10. – P. e309–e310. – DOI: 10.1016/j.jse.2017.03.019.
Mellion M.L., Widholm P., Karlsson M. et al. Quantitative muscle analysis in FSHD using whole-body fat-referenced MRI: composite scores for longitudinal and cross-sectional analysis // Neurology. - 2022. - Vol. 99, № 9. - P. e877-e889. - DOI: 10.1212/WNL.0000000000200757. - PMID: 35750498.
Panina OYu, Gromov AI, Akhmad ES, et al. Accuracy of fat fraction estimation using DIXON: experimental phantom study. Medical Visualization. 2022;26(4):147–158. doi: 10.24835/1607-0763-1160 EDN: JDIWXI
Park I., Oh M.J., Shin S.J. Effects of glenoid and humeral bone defects on recurrent anterior instability of the shoulder // Clin. Orthop. Surg. - 2020. - Vol. 12, № 2. - P. 145-150. - DOI: 10.4055/cios19060. - PMID: 32489534; PMCID: PMC7237246.
Provencher M.T., Midtgaard K.S., Owens B.D., Tokish J.M. Diagnosis and management of traumatic anterior shoulder instability // J. Am. Acad. Orthop. Surg. - 2021. - Vol. 29, № 2. - P. e51-e61. - DOI: 10.5435/JAAOS-D-20-00202. - PMID: 33275397.
Hsu C.Y., Pallathadka H., Jasim S.A., Rizaev J., Bokov D.O., Hjazi A. [et al.]. Innovations in cancer immunotherapy: A comprehensive overview of recent breakthroughs and future directions // Critical Reviews in Oncology/Hematology. – 2025. – Vol. 206. – Art. 104588.
Bayani A., Abosaoda M.K., Rizaev J., Nazari M., Jafari Z. [et al.]. Aptamer-based approaches in leukemia: a paradigm shift in targeted therapy // Clinical and Experimental Medicine. – 2025. – Vol. 25, No. 1. – Art. 186.
Saadh M.J., Khidr W.A., Alfarttoosi K.H., Bishoyi A.K., Ganesan S. [et al.]. Metal nanoparticles as a promising therapeutic approach for prostate cancer diagnosis and therapy: a comprehensive review // Medical Oncology. – 2025. – Vol. 42, No. 4. – Art. 83.
Mei S., Roopashree R., Altalbawy F.M.A., Rizaev J.A. [et al.]. Synthesis, characterization, and applications of starch-based nano drug delivery systems for breast cancer therapy: A review // International Journal of Biological Macromolecules. – 2024. – Vol. 280. – Art. 136058.
van Vucht N, Santiago R, Lottmann B, et al. The Dixon technique for MRI of the bone marrow. Skeletal Radiology. 2019;48(12):1861–1874. doi: 10.1007/s00256-019-03271-4