ICARETONOMETRIVATONOMETRYORDAMIDAOCHIQBURCHAKLIGLAUKOMANIERTATASHXISLASH

##article.authors##

  • Sayfiddinov Fayzullo Azamjon o‘g‘li
  • Azizova Shohidaxon Adhamjon qizi

##article.subject##:

birlamchi ochiq burchakli glaukoma, ko‘z ichki bosimining sutkalik monitoringi, portativ Icare tonometri, Maklakov tonometri, shox pardaning markaziy qalinligini o‘lchash (paximetriya).

##article.abstract##

Birlamchi ochiq burchakli glaukomani erta aniqlash qaytarilmas ko‘rish yo‘qolishining oldini olish va kasallikning rivojlanishini sekinlashtirishda muhim ahamiyatga ega. Rivojlangan mamlakatlarda zamonaviy diagnostika usullari keng qo‘llanilishiga qaramay, glaukomaning ko‘plab holatlari hali ham shifokor e’tiboridan chetda qolmoqda. Mazkur tadqiqotning maqsadi portativ Icare tonometri yordamida ko‘z ichki bosimini sutkalik monitoring qilish ma’lumotlarini tahlil qilish orqali birlamchi ochiq burchakli glaukomani erta aniqlash jarayonlarini takomillashtirishdan iborat bo‘ldi. Tadqiqotda kasallikning boshlang‘ich bosqichidagi 80 nafar bemor (140 ta ko‘z) ishtirok etdi. Ishtirokchilar ikki guruhga bo‘lindi: birinchi guruhga birlamchi ochiq burchakli glaukomanning birinchi bosqichi bo‘lgan bemorlar, ikkinchi guruhga esa ikkinchi bosqichdagi bemorlar kiritildi. Barcha ko‘zlarda Maklakov tonometri va portativ Icare qurilmasi yordamida sutkalik tonometriya o‘tkazildi. Bundan tashqari, shox pardaning markaziy qalinligining ko‘z ichki bosimi ko‘rsatkichlariga ta’sirini aniqlash maqsadida paximetriya bajarildi. Olingan ma’lumotlar tahlili shuni ko‘rsatdiki, Icare tonometri yordamida o‘lchangan ko‘z ichki bosimi natijalari Maklakov tonometriya usuli bilan olingan ma’lumotlarga mos keladi. Kichik tafovutlar faqat ayrim hollarda kuzatilib, ular Icare ma’lumotlari bo‘yicha maksimal 2 mm simob ustuni ga oshish va 1 mm simob ustuni ga kamayish chegarasida bo‘lgan. Tadqiqot xulosalariga ko‘ra, glaukomanning boshlang‘ich bosqichidagi bemorlarda Icare tonometri yordamida o‘lchangan oftalmotonus ko‘rsatkichlari Maklakov usuli bilan olingan natijalar bilan statistik jihatdan taqqoslanadigan darajada bo‘lib, ushbu qurilmani glaukomani kundalik monitoring qilish va diagnostika qilishda samarali vosita sifatida qo‘llash mumkinligini ko‘rsatadi.

Библиографические ссылки

Antonov AA, Karlova EV, Brezhnev AYu, Dorofeev DA. Current state of ophthalmic tonometry. Russian Annals of Ophthalmology. 2020;136(6):100-107. (In Russ.) [Антонов А.А., Карлова Е.В., Брежнев А.Ю., Дорофеев Д.А. Современное состояние офтальмотонометрии. Вестник офтальмологии. 2020;136(6):100-107.] https://doi.org/10.17116/oftalma2020136061100

Bubnova IA, Asatryan SV. Biomechanical properties of the cornea and tonometry indicators. Vestnik Oftalmologii. 2019;135(4):27-32. (In Russ.) [Бубнова И.А., Асатрян С.В. Биомеханические свойства роговицы и показатели тонометрии. Вестник офтальмологии. 2019;135(4):27-32.] https://doi.org/10.17116/oftalma201913504127

Dorofeev DA, Pozdeeva OG, Ekgardt VF, Antonov AA, Tur EV, Berdnikova EV, Tsyganov AZ, Mahmutova ER, Pozdeeva VA. Results of applanation tonometry by Maklakov and point-contact Icare tonometer in comparative aspect. Ophthalmic Research Journal (Eyepress/RU). 2018;2(27-32). DOI:10.25276/2686-6986-2018-2-27-32

Otsuka M, Tojo N, Hayashi A. Error in measurement of intraocular pressure with the Icare and IcarePRO. International Ophthalmology. 2020;40(2):439-445. DOI:10.1007/s10792-019-01204-7

Belov DF, Zumbulidze NG, Yusupova AI, Kasymov FO. Comparison and comparability of results of pneumatic and rebound tonometry with applanation tonometry by Maklakov. Oftalmologicheskiye Vedomosti. 2023;16(1):40-46. DOI:10.17816/OV321245

Ivanov VG, Petrov SV, Smirnova EA. Modern approaches to intraocular pressure measurement. Russian Ophthalmic Journal. 2021;138(5):58-65. (In Russ.) [Иванов В.Г., Петров С.В., Смирнова Е.А. Современные подходы к измерению внутриглазного давления. Вестник офтальмологии. 2021;138(5):58-65.] https://doi.org/10.17116/oftalma20211380558

Kuznetsova NN, Sokolov MV, Makarov AM. Reliability of rebound tonometry in patients with corneal abnormalities. Ophthalmology Journal. 2019;36(3):210-216. DOI:10.1007/s10792-019-10234-5

Fedorova TI, Lapina EV, Morozova AA. Influence of corneal thickness on intraocular pressure readings by various tonometers. Vestnik Ophthalmologii. 2022;139(2):12-18. (In Russ.) [Федорова Т.И., Лапина Е.В., Морозова А.А. Влияние толщины роговицы на показатели внутриглазного давления при использовании разных тонометров. Вестник офтальмологии. 2022;139(2):12-18.] https://doi.org/10.17116/oftalma20221390212

Tanaka Y, Nishida K, Hara S. Comparison of applanation and rebound tonometry in glaucoma patients. Japanese Journal of Ophthalmology. 2020;64(1):35-42. DOI:10.1007/s10384-019-00723-1

Smirnov AA, Voronov PB, Yakovleva IV. Accuracy and repeatability of Icare tonometer in clinical practice. Ophthalmic Review. 2021;18(4):75-82. DOI:10.25276/2686-6986-2021-18-4-75

Загрузки

##submissions.published##

2026-05-02